PVC-U Suction Filter
delivery time: 2-3 days
|
-for solvent welding, metric series |
|
|
||||||||||||||||||||||||||||||
Information:
Information:
Information:
Information:
Information:
Information:
Information:
|
UPVC PIPE SYSTEMS - GENERAL CHARAKTERISTICSDeveloped in 1930 in Germany, the UPVC (unplasticized polyvinyl chloride) is obtained by the process of polymerization vinyl chloride (a gaseous monomer). An highly reliable resin with high performance of thermal stability, chemical and mechanical resistance up to 60° C, is obtained by the presence of chlorine in the molecule of PVC. The different formulations obtained by the addition of suitable additives and stabilizers, make PVC the more versatile of the plastic materials, having several possibilities to be used in many applications of the fluids in pressure The UPVC represents one of the most economic solutions within the range of thermoplastic and metal materials. The system overcomes problems which can be encountered in the service lines of the industrial fields for the conveyance of corrosive chemical fluids and also in the distribution- treatment of general water. The main reasons for the preference of this system are attributed to the following characteristics of the resin: The UPVC is basically inert to most inorganic bases, acids, saline solutions and paraffinical/aliphatic hydrocarbons. It is not recommended for use with polar organic solvent, including chlorinated and aromatic types. The unique molecular structure grants a low coefficient of thermal conductivity (λ = 0,15 W/m °C according to ASTM C177). It virtually eliminates condensation and offers superior heat retention reducing heat loss through piping walls. Low permeability to oxygen and reduced water absorption (0,1% at 23°C according to ASTM D 570).Good resistance to ageing, thanks to the chemical and physical properties of the UPVC resin. All components are suitable for conveying potable water, beverages and food. The basic resins employed are all NSF approved. The material has excellent mechanical characteristics and good impact strength. These properties make the UPVC suitable for high service pressure (up to 4 6 10 16 bar at 20°C). The UPVC compounds, presents important characteristics of fire performance, in fact the flash ignition temperature is 399° C and it persists only in extreme conditions, e.g. if the Oxygen concentration is two times higher than the atmospheric one, or only in presence of external flame source. Flash ignition temperature: 399° C Limiting Oxygen Index: 45% Class UL 94 rating: V0 UPVC PIPES, UPVC FITTINGS, UPVC VALVESThe UPVC range is a complete range of fittings for solvent welding, threaded connection for use in the construction of process and service lines to convey industrial fluids at maximum operating temperatures of 60°C.The entire range is produced using UPVC resins compliant with the standards EN ISO 1452 and ISO 4422 and in observance of the requirements of DIN 8063 and EN ISO 15493 for the use of plastic pipes in industrial processes. FIP UPVC fittings are suitable for naval applications and classified according to Boureau Veritas. Main properties and characteristics: Good chemical resistance: UPVC resins guarantee excellent chemical resistance with regard to most acids and alkalis, aliphatic hydrocarbons and saline solutions. UPVC resins are also totally compatible for the handling of food grade fluids, treated and untreated drinking water, as well as demineralised water according to current national and international standards. Good thermal stability: mostly in the intermediate temperature range between 20°C and 50°C, UPVC finds its ideal application in industrial and water supplies, assuring optimal performance in terms of mechanical resistance, good rigidity, low coefficients of thermal expansion and optimal safety factors in service. Lifetime: UPVC resins feature is an high value in the material strength (Minimum Required Strength MRS > 25.0 Mpa at 20°C) and an extremely extended lifetime. The possibility to choice between different jointing systems make low costs in the operations of installation. ISO 15493 Plastics piping systems in UPVC for industrial applications. EN 1452 Characteristics of UPVC fittings and pipes of piping systems for water supply. ISO 727 Pipes and fittings in UPVC. Dimensions and tolerances metric series. ISO 4422 Characteristics of UPVC fittings of piping systems for water supply. DIN 8063 UPVC fittings, dimensions. KIWA (Keurings Institut Voor Waterleiding Artikelen Holland) KIWA BRL K 504 e KIWA BRL 502 Characteristics of UPVC fittings and pipes of piping systems for water supply. BSI (British Standard Institution UK) BS 4346-1 Characteristics of UPVC fittings of piping systems for fluids under pressure. BS 3505-3506 Characteristics of UPVC pipes for industrial fluids and cold water. UNI ISO 228/1:1983 UPVC fittings with threaded connections. DIN 2999 UPVC fittings with threaded connections. BS 21 UPVC fittings with threaded connections. ISO R7:1984 UPVC fittings with threaded connections sealing tight. ISO 161/1 UPVC pipes and fittings dimensions, metric series. DIN 8062 UPVC pipes dimensions. ASTM D696 e DIN 53752 Coefficient of linear thermal expansion, test and method. DVS 2204-1 Solvent welding of thermoplastic materials UPVC UNI 11242 Solvent welding of UPVC pipes, fittings and valves. The production of the UPVC lines, is in accordance with the highest quality standards and in full observance of the environmental practices imposed by current legislation. All products are manufactured in accordance with ISO 9001certified quality assurance programme. For more information please visit our website www.kwerk.de IIP N. 122 Istituto Italiano dei Plastici (Italian Institute of Plastics) UPVC fittings according to UNI EN 1452 ACS France (Attestation de conformité Sanitaire) N. 98 MAT NY 418 Suitability of UPVC for alimentary applications. BSI (British Standard Institution UK) Licence N. KM 05802 UPVC fittings according to BS 4346-1. NSF (National Sanitation Foundation USA) Certificate N. 11370/11371A Suitability of UPVC for use with drinking water. WRAS (Water regulations advisory scheme - UK) Certificate N. M103019 Suitability of UPVC for use with drinking water. KIWA (Keurings Institut Voor Waterleiding Artikelen Holland) Certificato N. K5034/01 UPVC fittings according to KIWA BRL K504 IRH FIP UPVC fittings are acknow-ledged by IRH for ACS Certificate N. 05 MAT NY 006 BUREAU VERITAS (France) Certificate N. 07123 / C0 BV Suitability of UPVC for transport and treatment of sanitary water and of conditioning for naval applications.FIP UPVC fittings are certified in accompliance with Ucrainian hygienic, safety and quality regulation. Certificate N. UA1.094.0052575-04 RINA Registro Italiano Navale (Italian Register Naval) Certificate N. MAC/36401/TO/01 Suitability of UPVC for transport and treatment of sanitary water and of conditioning for naval applications. |
INFORMATION TO OUR DELIVERY PROGRAM |
OUR - PREMIUM PARTNERS - |
|
|
|
|
|
|
|